• High Power Linear DC Regulated Power Supply 200V200A
  • High Power Linear DC Regulated Power Supply 200V200A
  • High Power Linear DC Regulated Power Supply 200V200A

High Power Linear DC Regulated Power Supply 200V200A

Output Voltage: 0 ~ 200V
Output Current: 0 ~ 200A
Circuit Mode: AC/DC Power Frequency Transformation
Working Mode: Constant Voltage / Constant Current
Output Setting: 10-Turn Potentiometer
Output Display: LED or LCD
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Jiangsu, China

Basic Info.

Model NO.
LVLP - 0200 - 0200T
Protection
Ov, Oc, Oh, Lack Phase
Remote Control
0~10V / 4~20mA Analog Signal Control
Cooling Method
Forced-Air Cooling
Application
Capacitor Burn-in, Energizing, Relay and Resistor
Transport Package
Plywood Case
Specification
AC/DC transformer, filter, inductance
Trademark
IdealTek
Origin
China
HS Code
85044019
Production Capacity
10PCS/Month

Product Description

LVLP Series Linear DC Power Supply
  1. Power range: 40KW
  2. Voltage range: 0V ~ 200V
  3. Current range: 0A ~ 200A
  4. Precise voltage and current setting and measurement capabilities
  5. OVP, OCP, OTP and short circuit protections etc.
High Power Linear DC Regulated Power Supply 200V200A
Overview
LVLP series is linear DC power supply uses power frequency transformer AC/DC conversion technology and matured filtering circuit to ensure pure and & stable DC output
As it uses power frequency transformer, it does not have high frequency radiation interference like switching mode power supply has, so it is suitable for some special conditions that sensitive to EMC. And by its matured and perfect filtering circuit, it has super low ripple and very good output precision; also it has complete protection functions
As features above, this series is mostly used for capacitor, relay and resistor burn-in test and other kinds of test that needs high precision & low ripple DC output.
High Power Linear DC Regulated Power Supply 200V200A
Features
  1. Over 500 models, output voltage: 0 ~ 800V, output current: 0 ~ 500A, output power: 0KW-400kW
  2. Constant voltage mode and constant current mode, automatic switchable, output voltage / current continuously adjustable from 0 to rated value.
  3. Over voltage protection: Over voltage value continuously adjustable from 0 to 110% rated value, auto-shut down when output voltage exceeds the over voltage set point
  4. Short protection: Withstand short-circuit under start-up or any working modes, sound & light alarm when output has short.
  5. Over load protection: Auto-tripping when power supply or load has fault and output current exceeds 1.5 times of rated value.
  6. Current-limit protection: User set current-limit value; output current will be limited at current-limit value when load has fault.
  7. Output display: Voltage & current both LED digital display.
Application
  1. Electrolysis capacitor burn-in, tantalum capacitor energizing, charging.
  2. Resistor, relay, motor, transistor and other electronic components burn-in and routine test.
  3. Stereo equipment test, vehicle electronics test
  4. Different kinds of current protector test.
  5. Lab, electronic device and automatic test equipment
  6. Electronic test device, production line equipment, communication equipment.
  7. Electrolysis, electroplating, electrochemical equipment.
  8. Other conditions need high precision DC output.
Optional functions
  1. Short alarm: sound & light alarm when output voltage lower than 1% of rated value and current higher 110% of rated value.
  2. Automatic off-load and discharging: when power supply shutdown, power supply will automatically cut off load and discharge electric in load for safety.
  3. Output display: LCD touch screen display.
  4. Pulsing working: could add time controller to be pulsing power supply.
  5. Communication port: RS232/RS485 for connection with computer to be remote controlled & monitored by computers.
  6. Analog signal: 0 ~ 5V (10V) or 4 ~ 20mA analog signal for output voltage & current control.
Specifications
Input Voltage Three-phase 380Vac±10% 
Frequency 50Hz±10% 
Output Output modes DC C.C. / C.V. 
Rated power 40 kW 
Output voltage adjusting range 0V ~ 200V 
Output current adjusting range 0A ~ 200A 
Accuracy (C.V.) Line regulation ≤0.1% Of the rated value ± 1 digit (output voltage change ratio under input ±10% change) 
Stability during 8 hrs≤0.3% of the rated value (output voltage change ratio due to 8 hours continuously working) 
Temp. coeff.offset ≤0.04% of the rated value/ºC(output voltage change ratio due to environment temperature changes) 
Load regulation ≤0.3% of the rated value ± 1 digit (output voltage change ratio due to output current change from 0 to rated value) 
Accuracy (C.C.) Line regulation ≤0.1% Of the rated value ± 1 digit (output current change ratio under input ±10% change) 
Stability during 8 hrs≤0.3% of the rated value(output current change ratio due to 8 hours continuously working) 
Temp. coeff.offset ≤0.04% of the rated value/ºC(output current change ratio due to environment temperature changes) 
Load regulation ≤0.3% of the rated value ± 1 digit (output current change ratio due to output voltage change from 0 to rated value) 
Ripple +noise (RMS) CV: ≤0.01% of the rated value+10mV (80%~100% rated output) (single-phase input)
≤0.1% of the rated value+10mV (80%~100% rated output) (three-phase input)
CC: ≤0.2% of the rated value+10mA (80%~100% rated output) 
Efficiency ≥75% (measured @ 80%-100% resistive loading) 
Working ability Withstand long-term continual working. 
Setting & Display Control mode 10-turn Potentiometer (with-lock) 
Display mode 41/2 Digital LED 
Display error Voltage ≤±1%±1digit (range:5%~50% of the rated value) 
Current ≤±0.5%±1digit (range:50%~100% of the rated value) 
Display resolution Voltage Four-digit display with a minimum resolution of 0.01V / 0.1V / 1V
(As per rated output values) 
Current Four-digit display with a minimum resolution of 1mA / 0.01A / 0.1A
(As per rated output values) 
Load characteristic On demand 
Protection & Monitoring functions Input protection Input lack voltage and lack phase protection.
(available for three-phase input) 
Output over voltage protection (OVP) Output over voltage protection value settable.
Power supply automatically cuts off output and alarms when output has over voltage. 
Output over current protection (OCP) Output over current protection value settable.
Power supply automatically cuts off output and alarms when the output has over current. 
Over temperature protection (OTP) Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds 85 °C. 
Output short-circuit protection Withstand short-circuit and alarm. 
Noise ≤70dB 
Protection degree IP20 
Cooling method Forced air cooling 
Working conditions Ambient temperature -10ºC~40ºC 
Humidity 10%~80%(non-condensing) 
Height ≤1000m 
Accessories Fuse * 1 set
Operation manual * 1pc 
Input Voltage: Power source voltage can be changed to others on request.
Custom-made specifications are on request.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
<100 square meters