40kv 10kw High Voltage Power Supply

Output Type: Single
Warranty: 1 Year
Output Power: 10kw
Input Voltage: 380V
Connection Mode: Series Switching Power Supply
Starting Mode: Self-excited Switching Power Supply
Customization:
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Jiangsu, China

Basic Info.

Model NO.
HP-(N/P)10KW-40KV
Voltage Regulating Mode
Width Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
One-way Transmission
Modulation System
PWM
Brand
Idealtek
Output Voltage
0 ~ 40kv
Output Current
0 ~ 250mA
Output Polarity
Positive or Negative
Circuit Mode
IGBT Full Bridge Circuit
Working Mode
Constant Voltage / Constant Current
Output Display
LED
Remote Control
0~10V / 4~20mA Analog Signal Control / RS Ports
Cooling Method
Forced-Air Cooling or Water Cooling or Oil Immerse
Protection
Ovp, Ocp, Short Circuit and Load Discharging PRO
Color
Ral7035
Transport Package
Plywood Case
Specification
IGBT & HF transformer
Trademark
iDealTeknic
Origin
China
HS Code
85044019
Production Capacity
50PCS/Month

Product Description

HP High Power High Voltage DC Power Supply
Model: HP-(N/P)10KW-40KV

 
  1. Power range: 10KW
  2. Voltage range: 40KV
  3. Current range: 250mA
  4. Industrial-grade chassis, rugged and reliable.
  5. Precise voltage and current setting and measurement capabilities
  6. OVP, OCP, short circuit and load discharging protections etc.
40kv 10kw High Voltage Power Supply
Overview
The HP Series power supply is a high-power, high-voltage power supply series. Its power ranges from 5kW to 15kW (single unit) with voltage output from 1KV to 60kV.
The series is mainly equipped with a standard 19-inch chassis structure for easy integration of high-voltage systems.
The high-power inverter used in the HP series power supply adopts the series resonant inverter designed by our company. The input end is directly installed on the power module with ultra-low loss filter capacitor. The input rectification, filtering and inverter are all integrated and installed onto one radiator.
Air-cooled or water-cooled or oil-cooled and water-cooled would be adopted according to the voltage and power rating to ensure good heat dissipation.
The high voltage transformer uses a distributed rectifier transformer. These characteristics give the series of power supplies very high reliability and extremely low energy storage.
40kv 10kw High Voltage Power Supply
Features
  1. Professional high voltage power supply with continuous HV output ability.
  2. Output voltage: 40KV
  3. Output power: 10KW
  4. Output voltage & current both 0 ~ 100% rated value continuously adjustable.
  5. CV & CC working modes
  6. Max. charging/discharging repetition frequency: 50Hz
  7. Charging/discharging repetition accuracy:  <2% (@50Hz)
  8. Forced air cooling / Oil-immersed cooling with rugged design.
Optional functions
  1. 0 ~ 10V analog signal control (DB25 interface) (+AC)
  2. RS communication interface (RS232 / RS485 optional) (+RC)
Block diagram & Principle description
Working principle
The IGBT full bridge inverter and the Series Resonant Tank circuit are the key components in this power supply.
The series resonant inverter converts input voltage source to a equivalent current source, each pulsing is equivalent to an energy pack, which is sent to output load or output filtering capacitor after HV rectifying.
Different output voltage and current corresponds to different output pulsing frequency, adjusting pulsing frequency leads to output voltage and current changes.
Functional parts
The HP unit is made up of four different functional parts as shown below:
40kv 10kw High Voltage Power Supply
Rectifier Part
This stage takes three-phase 380Vac or 440Vac input, then after rectifies and filters, it creates a 600Vdc pulsing DC output.
 
High Frequency DC/AC Part
This stage uses an IGBT (Insulated Gate Bipolar Transistor) full bridge circuit to convert the pulsing DC to a high frequency AC waveform that feeds the next stage.
 
Series Resonant Tank Part
This part is an inductor in series with a capacitor. This LC network defines the characteristic impedance of the system and the frequency at which the AC current resonant.
 
High Voltage AC/DC Part
This part uses a transformer to step up the high frequency AC the necessary high voltage level. A rectifier circuit is then used to convert the high voltage, high frequency AC to the high voltage DC.
Specifications
Input Voltage Three-phase 380Vac (input tolerance: 10%)
Frequency 50Hz/60Hz
Current As per output power.
Output Rated power 10KW (Max.)
Output voltage adjusting range 0 ~ 40KV
Output current adjusting range 0A ~ 250mA
Output polarity Positive or Negative (both available)
Client must choose one output polarity before ordering.
Output voltage regulation precision ≤0.1%
Output voltage accuracy ≤0.1%
Line regulation ≤0.1% for no load to full load at output.
Load regulation ≤0.1% for ±10% change in input voltage.
Output connection HV connector and line provided by IdealTek.
Power factor ≥0.92
Efficiency ≥90% (measured @ 80% ~ 100% resistive load)
Setting & Display Output control mode 10-turn potentiometer on front panel.
Display mode 41/2 LED digital display
Protection & Monitoring functions Input protection Input lack voltage and lack phase protection.
Output over voltage protection (OVP) Output over voltage protection value settable.
Power supply automatically cuts off output and alarms when output has over voltage.
Over temperature protection (OTP) Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds power supply threshold value.
Load discharging protection When the load has discharging due to insufficient safety distance between load and ground, the power supply shutdown the high voltage output, and then restarts, so cycle like this till the discharging fault is eliminated.
Short circuit protection When a short circuit occurs between the load and the ground, the power supply works in constant current mode, the current is limited to the maximum value, and the voltage drops to 0 to protect the internal inverter from damage.
Over current protection When the users' load exceeds the rated load and cause over-loading, the power supply works in constant current mode, the power supply output current does not change, and output voltage decreases.
Noise ≤65 ~ 70dB
Protection degree IP20
Cooling method Forced air cooling / Oil-immersed cooling.
Working environment conditions Ambient temperature -10ºC~40ºC
Humidity 10%~90%(non-condensing)
Height ≤2000m
Storage environment conditions Ambient temperature -20ºC~60ºC
Humidity 10%~90%(non-condensing)
Height ≤4000m
Size (W*H*D) (mm) 19" 9 ~ 10U cabinet with 800mm Depth
Weight Approx. 95 ~ 120Kg
(depends on power rating)
  1. Note: every power supply has 48 hours full load burn-in test @ 40ºC
  2. The product can be customized on demand.
Safety caution
  1. This power supply has HV output, only professional person could operate it.
  2. Please check power supply as below before start-up.
  3. Keep power supply clean and good ventilation.
  4. HV input & output connectors or HV load no touch anything.
  5. Please check back current of load well connected with GND bolt at the back of power supply.
Drawings (for reference only)
19'' 9 ~ 10U cabinet (RAL7035)
40kv 10kw High Voltage Power Supply

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
1000000 RMB
Plant Area
<100 square meters