Output Type: Triple
Warranty: 1 Year
Output Power: 5kVA~600kVA
Input Voltage: Full Range
Connection Mode: Parallel Switching Power Supply
Starting Mode: Self-excited Switching Power Supply
Customization:

Contact Supplier

Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
VFP-T Series
Voltage Regulating Mode
Width Modulation Type
Power Supplying System
Terminal Power Distribution Equipment
Energy Transmission
One-way Transmission
Modulation System
PWM
Certification
CE
Brand
Idealtek
Output Voltage
0V ~ 150V / 0~300V
Output Frequency
45Hz ~ 70Hz, 50 / 60 / 100 / 200Hz
Circuit Mode
IGBT/PWM Pulsing Width Modulating Mode
Working Mode
Constant Voltage / Constant Frequency
Output Setting
Key Button Plus 10-Turn Potentiometer
Output Display
LED or LCD
Protection
Ov, Oc, Oh, Over Load, Short
Remote Control
0~10V / 4~20mA Analog Signal Control / RS Ports
Cooling Method
Forced-Air Cooling
Application
Household Applicances Test, Labs
Transport Package
Plywood Case
Specification
HF transformer, filtering circuit, IGBT
Trademark
IdealTek
Origin
China
HS Code
85044019
Production Capacity
300PCS/Month

Product Description

VFP-T Series Three Phase Variable Frequency AC Power Supply
  1. Power range: 3KVA ~ 600KVA
  2. Voltage range: 0 ~ 150Vac / 150 ~ 300Vac
  3. 45Hz ~ 70Hz variable output frequency, 50 / 60 / 100 / 200Hz static output frequency.
  4. Precise voltage and current setting and measurement capabilities
  5. Small size, high efficiency and low energy consumption.
  6. OVP, OCP, OTP and short circuit protections etc.
Vfp-T Series Three Phase High Power Variable Frequency AC Power Supply
 
Overview Vfp-T Series Three Phase High Power Variable Frequency AC Power Supply
 
The VFP-T series is three-phase output model which has various output range from 3KVA to 600KVA, it has high resolution & stability and full protection functions, output voltage & frequency continuously adjustable and easy operation-panel. It's widely used as a simulated AC input for equipment or home appliance testing.
Block diagram
Vfp-T Series Three Phase High Power Variable Frequency AC Power Supply
 
Features
  1. Output voltage & frequency adjustable via potentiometer or key button
  2. Output Range: Voltage - Low level: 0 ~ 150V, High level: 150 ~ 300V or 0 ~ 300V continuously adjustable (best simulate input voltage of different countries)
  3. Frequency: 45 ~ 70Hz (adjustable)
    50Hz / 60Hz / 100Hz / 200Hz / 400Hz (fixed)
  4. Power: 3KVA ~ 200KVA for selection.
  5. High output voltage accuracy and output frequency stability
  6. Response time: 2ms
  7. 0.5% load stability.
  8. ±1.5% waveform distortion (resistive load)
  9. High-accuracy display for output voltage, current, frequency, power & power factor.
  10. Full Protection functions (over voltage, over load, over temp, over current, short-circuit)
  11. Friendly Operation Panel.
Optional functions
  1. 0 ~ 5V / 0 ~ 10V / 4 ~ 20mA analog signal control. (DB port) (+AC)
  2. RS communication interface (RS232 / RS485 optional) (+RC)
Application
  1. For electron-products testing, debugging, powering for electro-instrument
  2. Electromotor, electron manufacturing, IT industry, computer, labs and so on.
  3. Other situations that need frequency conversion power supply
Specifications
Output capacity 3KVA 6KVA 10KVA 15KVA 20KVA 30KVA 45KVA 60KVA 100KVA 120KVA 150KVA 200KVA 300KVA 400KVA 500KVA 600KVA
Circuit mode IGBT/PWM pulsing width modulating mode
AC input Single-phase 220Vac / 50Hz, 60Hz Three-phase 380Vac / 50Hz, 60Hz
AC output Phase Three-phase (phase difference: 120±2°)
Voltage Low level 0~150V (phase voltage) / 0 ~ 260V (line voltage) (special requirements can be customized)
High level 0~300V (phase voltage) / 0 ~ 520V (line voltage) (special requirements can be customized)
Frequency 45~70Hz (adjustable)
50Hz, 60Hz, 100Hz, 200Hz, 400Hz (fixed)
(special requirements can be customized)
Max. Current 0 ~ 150Vac 8.4A 16.8A 28A 42A 50A 84A 125A 168A 276A 336A 416A 556A 834A 1112A 1400A 1667A
150 ~ 300Vac 4.2A 8.4A 14A 21A 25A 42A 63A 84A 138A 168A 208A 278A 417A 556A 700A 833A
Frequency Stability   ≤±0.1%
Load Stability ±0.5%
Harmonic distortion ≤1.5% (resistive load)
Response time ≤2ms
Output display Voltage, Current, Power, Frequency & Power factor all 4-digit LED display.
Display resolution Voltage meter: 0.1V
Current meter: less than 4A: 0.001A   more than 4A: 0.01A
Power meter: less than 200W: 0.1W   more than 200W: 1W
Frequency meter: 0.1Hz
Power factor: 0.001 (optional)
A, B, C three phase parameters switchable display
Protections Auto tripping and alarm when over voltage, over load, over temp, over current and short-circuit.
(Input & output no fusing breaker)
Cooling mode Forced air-cooling
Working Temperature 0°C~45°C
Relative humidity 0 ~ 90% (non-condensing)
Size (W*H*D) (mm) 430*650*650 610*950*725 700*1200*1020 700*1340*1280 800*1340*1420 950*1500*1800 850*1200*1020 850*1200*1600 900*1400*1600
Weight (Kg) 92 125 180 245 360 400 550 650 `1050 1250 1350 2050 3050 4050 5600 6300
The product can be customized on demand.
Maintenance
  1. Check whether the bolts or moisture loosen regularly
  2. Check whether water leakage at pipe connection regularly
  3. Check whether any leaking of water pipe connection regularly.
  4. Regularly open the box side plate, cleaning dust inside.
  5. Regularly with clip-on ammeter check three-phase input current that it is abnormal and serious drift phenomenon, if abnormal, contact the supplier in time.
  6. Specially assigned person for equipment maintenance.
Installation environment
  1. Ambient temperature: Please have the power source working in safe temperature range (0ºC ~ 45ºC) or it would affect life of power source.
  2. Please install the power source at least 50cm distant from surroundings to have better ventilation.
  3. Please install the power source away from vibration (less than 0.6G), especially equipment like puncher.
  4. Keep the power source away from direct sunshine, humidity or place with water globule.
  5. Keep the power source from corrosive, flammable & explosive gas.
  6. Keep the power source away from oil stain, dust & metallic dust.