MTP Series High Power Switching DC Power Supply | ||||||
|
||||||
|
||||||
Overview | ||||||
MTP series high-precision DC test power supply adopts full-bridge phase-shift soft-switching technology, high output efficiency and small size; it has two-stage conversion circuit structure and double closed-loop control circuit system to ensure power supply with high stability and good output precision. It can meet the testing needs of power electronics industry, electronic device industry, new energy motor industry and power battery industry. |
||||||
Block diagram | ||||||
Features | ||||||
|
||||||
Optional functions | ||||||
|
||||||
Specifications | ||||||
Input | Connection mode | Single - phase, two - wire + GND Three - phase, four - wire + GND Three - phase, three - wire + GND |
||||
Voltage | 220V±10% 380V±10% |
|||||
Frequency | 50Hz/60Hz±5Hz | |||||
Output | Rated power | **** kW | ||||
Output voltage adjusting range | 0V ~ ****V | |||||
Output current adjusting range | 0A ~ ****A | |||||
Output voltage precision | 0.5%FS | |||||
Output current precision | 0.5%FS | |||||
Line regulation | ≤0.2%FS | |||||
Load regulation | ≤0.2%FS | |||||
Temperature drift | 0.04%FS/ºC | |||||
Time drift | 0.3%FS | |||||
Ripple (Vr.m.s.) | ≤0.5% F.S (measured @ rated voltage with 80%-100% resistive loading) | |||||
Response time | ≤10ms / 20ms (measured @ 10%-90% resistive loading) Depends on output power rating |
|||||
Efficiency | ≥88% (measured @ 80%-100% resistive loading) | |||||
Working ability | Withstand long-term continual working. | |||||
Setting & Display | Control mode | Local | Front panel button control / LCD touch screen Depends on output power rating |
|||
Remote | RS485 communication interface. In line with MODBUS-RTU standard. |
|||||
Display mode | LED digital display / LCD Depends on output power rating |
|||||
Set & Display error | Voltage | 0.5%FS | ||||
Current | 0.5%FS | |||||
Display resolution | Voltage | Four-digit display with a minimum resolution of 0.01V (Ue ≤ 30V) |
||||
Four-digit display with a minimum resolution of 0.1V (30V < Ue < 1000V) |
||||||
Four-digit display with a minimum resolution of 1V (Ue ≥ 1000V) |
||||||
Current | Four-digit display with a minimum resolution of 0.01A (Ie ≤ 50A) |
|||||
Four-digit display with a minimum resolution of 0.1A (50A < Ie < 1000A) |
||||||
Four-digit display with a minimum resolution of 1A (Ie ≥ 1000A) |
||||||
Automatic voltage compensation | ≤5V (Ue ≤ 100V) | |||||
≤10V (100V<Ue ≤ 300V) | ||||||
≤15V (300V< Ue ≤ 1000V) | ||||||
Over-loading ability | Iout≤1.25 Ie, output shutdown after 600s. Iout≤1.5Ie, output shutdown after 60s. Iout≤2Ie, output shutdown after 5s Iout>2Ie, output shutdown immediately. |
|||||
Protection & Monitoring functions | Output over voltage protection (OVP) | Output over voltage protection value settable. Power supply automatically cuts off output and alarms when output has over voltage. |
||||
Output over current protection (OCP) | Output over current protection value settable. Power supply automatically cuts off output and alarms when the output has over current. |
|||||
Over temperature protection (OTP) | Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds 85 °C. | |||||
Output short-circuit protection | Power supply automatically cuts off output and alarms when the output has short-circuit. | |||||
Automatic voltage compensation protection | Output over compensation protection / compensation line reverse-connected protection | |||||
Noise | ≤55 ~ 78dB Depends on output power rating |
|||||
Protection degree | IP20 | |||||
Cooling method | Forced air cooling | |||||
Safety features | Insulation resistance | ≥20MΩ | ||||
Withstand voltage ability | 60s test @ 2000VDC, no flash-over or spark-over. | |||||
Grounding inductance resistance | ≤100mΩ | |||||
Working conditions | Ambient temperature | 0ºC~45ºC | ||||
Humidity | 10%~90%(non-condensing) | |||||
Height | ≤2000m | |||||
Size (W*H*D) (mm) | Depends on output power rating | |||||
Functions | ||||||
Working modes
|
||||||
The power supply has two working modes: CV / CC mode and CV / OC mode, customers can select different working modes according to actual use requirements.
CV / CC mode Under CV / CC mode, the output voltage and current of power supply are continuously adjustable from 0 to the rated value.Power supply works either in constant voltage (CV) or constant current (CC) state, the CV & CC working state are automatically switchable, the switching conditions are determined by the voltage & current set values and the customer's load resistance value. For details, please refer to the following figure.In CV state, the output voltage is adjustable and regulated; the output current varies with the output voltage value and the customer load resistance.In CC state, the output current is adjustable and regulated, the output voltage varies with the output current value and the customer load resistance.
CV / OC mode
Under CV / OC (over current) mode, besides CV function, power supply still has over-current working ability, (OCP is invalid in this mode), detailed parameters as below:0% ~ 100% rated current value: continuous working with load100% ~ 125% rated current value: withstand 600s continuous working125% ~ 150% rated current value: withstand 60s continuous working150% ~ 200% rated current value: withstand 5s continuous workingPower supply automatic protected and stops output when Max. Over-current time exceeded. |
||||||
OVP & OCP value setting function
|
||||||
OVP and OCP value could be set via front control interface, power supply could automatically stop output when output voltage or output current exceeds the set protection values. OVP: over voltage protection value. OCP: over current protection value. |
||||||
Automatic line voltage drop compensation function
|
||||||
Power supply has automatic line voltage drop compensation terminals, connect the terminals to load ends; power supply could automatically detect load end voltage value and make voltage compensation for line voltage drop. Meanwhile, this function could detect if load connection is reverse connected or not. | ||||||
Self-discharging function
|
||||||
The power supply has built-in discharging circuit, which would be automatically activated to quickly release the energy stored in the output capacitor after the power supply stops output, so as to prevent personal injury caused by accidently touching the output terminal right after the power supply stops. | ||||||
Short-circuit protection
|
||||||
The power supply can adapt to two kinds of short-circuit conditions as below: If the power supply has short-circuit before starting output, then power supply can be normally started and running continuously for a long time. If power supply has a sudden short-circuit during running with load, then power supply would automatically stop output and gives sound alarm, LEDs on front panel would display corresponding alarm code. |
||||||
Communication port
|
||||||
Power supply equipped with RS485 communication port for remote control and monitoring via PC. | ||||||
Key technology introduction | ||||||
Air duct design
|
||||||
Full-sealing independent "Chimney" type air duct design adopted, the inner circuit uses independent cooling fan to improve the product heat dissipation effect, and the air inlet has dustproof measures, which greatly reduces dust and debris entering the power supply. The radiator and fan can be cleaned and maintained separately The heat dissipation system undergoes rigorous simulation and actual testing, and is designed with reliability in consideration of national standards and enterprise standards to ensure that the device with low temperature rise and long life. |
||||||
Core component
|
||||||
The key and important core devices are all internationally renowned brands, and high-quality devices ensure the stability and reliability of product operation. | ||||||
Installation environment | ||||||
|
||||||
Standard Chassis | ||||||
3KW | ||||||
6KW | ||||||
10KW ~ 15KW | ||||||
15KW ~ 20KW | ||||||
30KW ~ 45KW | ||||||
|
||||||
45KW ~ 60KW | ||||||
|
||||||
75KW ~ 100KW | ||||||
120KW ~ 200KW | ||||||
|
||||||
250KW ~ 450KW | ||||||
500KW ~ 2000KW |