HPS High Power High voltage DC Power Supply
Model: HPS-(N/P)100KW-150KV
|
||||
|
|
|||
Overview | ||||
The HPS series is developed based on the HP series power supply with internal modules in parallel-connection. This series of power supplies are featured for excellent electronic characteristics such as high accuracy, high precision and high stability. Its output voltage ranges from 5KV to 300KV, and its power rating has reached a wide range of 50KW ~ 1000KW. The power supply adopts hybrid cooling mode: Air-cooling for the control part, water cooling plus oil-cooling for main power components, internal module redundancy technology and perfect protection circuit to ensure the excellent reliability of the power supply under high voltage and high-power output. The power supply is mainly customized according to the applications, and the industries we have engaged includes mining gravel, super power capacitor charging, electron beam melting, and ray tube veteran etc. |
||||
Features | ||||
Short circuit protection
High-voltage power supply is equipped with a special output current short-circuit suppression circuit to prevent high-voltage power supply output discharging and sparking short circuitCould accept long-term discharge sparking and short-circuiting for special-purpose environments also can be made to be short-circuit protection. The high-voltage power supply is equipped with a special discharging protection circuit to ensure that other equipment and the power supply are not damaged. Ultra-short protection time: When the sensitive current detection circuit detects that the current exceeds the protection set value, power supply would enable the current-limit & power-limit circuit to ensure that the output current is controlled within the set value. The protection startup time is within 10 microseconds and can be achieved in 3 microseconds as requirements. Double current-protection circuit The first-level protection: The dynamic current detection control circuit stabilizes the current at the set value dynamically. The power supply voltage-drop flash detection circuit detects short-circuit and sparking condition of the load at the first time, and enables the protection circuit in time. Redundancy technology The application of this technology improves the stability of some systems that cannot be powered down. Module design Overvoltage protection Overcurrent protection Overload protection Overheat protection Grid input protection Constant voltage (CV) & Constant current (CC) Linkage adjustment Surge limit |
||||
Optional functions | ||||
|
||||
Block diagram & Key technology | ||||
Key technology | ||||
|
||||
Block diagram | ||||
|
||||
Specifications | ||||
Input | Connection mode | Three-phase, four-wire (PE), TN-S supply mode. | ||
Voltage | 380Vac (input tolerance: 10%) | |||
Frequency | 50Hz/60Hz±10% | |||
Current | Depends on output power rating | |||
Output | Rated power | 100KW (Max.) | ||
Output voltage adjusting range | 0 ~ 150KV | |||
Output current adjusting range | 0A ~ 667mA | |||
Output polarity | Positive or Negative (both available) Client must choose one output polarity before ordering. |
|||
Working mode | Constant voltage (CV) / Constant current (CC) | |||
Accuracy (C.V.) | Line regulation | ≤0.2% FS (Output voltage change rate only caused by changes of input voltage over a specified range of variation) | ||
Load regulation | ≤0.2% FS (Output voltage change rate only caused by full range load changes) | |||
Accuracy (C.C.) | Line regulation | ≤0.2% FS (Output current change rate only caused by changes of input voltage over a specified range of variation) | ||
Load regulation | ≤0.2% FS (Output current change rate only caused by full range load changes) | |||
Ripple (r.m.s) | ≤0.3% FS (measured @ 80% ~ 100% rated output) | |||
Output connection | HV connector and line provided by IdealTek. | |||
Power factor | cosΦ= 0.92 | |||
Efficiency | ≥90% (measured @ 80% ~ 100% resistive load) | |||
Working ability | Withstand long-term continuous working at full load. | |||
Setting & Display | Output control mode | Voltage & Current continuously adjustable via 10-turn potentiometer or touch screen with self-locking function. (Depends on output power rating) |
||
Display mode | 41/2 LED digital display or LCD (Depends on output power rating) |
|||
Display error | ≤±0.5%FS ± 1digit (range: 50%~100% of the rated value) | |||
Display resolution | As per output voltage & current values. | |||
Protection & Monitoring functions | Input protection | Input lack phase protection. | ||
Over voltage protection (OVP) |
Output over voltage protection value settable. Power supply automatically cuts off output and alarms when output has over voltage. |
|||
Over current protection (OCP) |
When the users' load exceeds the rated load and cause over-loading, the power supply works in constant current mode, the power supply output current does not change, and output voltage decreases. | |||
Over temperature protection (OTP) | Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds 85 °C. | |||
Short circuit protection | When a short circuit occurs between the load and the ground, the power supply works in constant current mode, the current is limited to the maximum value, and the voltage drops to 0 to protect the internal inverter from damage. | |||
Inverter transient protection response time | ≤10us | |||
Start-up overshoot | No start-up overshoots. | |||
Short protection mode | CC working when short-circuit. | |||
Noise | ≤65 ~ 75dB | |||
Protection degree | IP20 | |||
Cooling method | Forced air cooling / Oil-immersed cooling / Oil-immersed cooling + Water cooling + air cooling HV oil tank: oil-immersed cooling Rectifier & Inverter part: water cooling (external water injection required) Other parts: Forced air-cooling. Direction: The lower part of the left and right sides - In and Top - Out wind |
|||
Working environment conditions | Ambient temperature | -10ºC~40ºC | ||
Humidity | 10%~80%(non-condensing) No conductive dust, gas or steam that destroys the insulating medium No severe vibration and shock, good ventilation. |
|||
Height | ≤2000m | |||
|
||||
Safety caution | ||||
|