Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HP High Power High voltage DC Power Supply Model: HP-(N/P)10KW-50KV |
|||
|
|||
Overview | |||
The HP Series power supply is a high-power, high-voltage power supply series. Its power ranges from 5kW to 15kW (single unit) with voltage output from 1KV to 60kV. The series is mainly equipped with a standard 19-inch chassis structure for easy integration of high-voltage systems. The high-power inverter used in the HP series power supply adopts the series resonant inverter designed by our company. The input end is directly installed on the power module with ultra-low loss filter capacitor. The input rectification, filtering and inverter are all integrated and installed onto one radiator. Air-cooled or water-cooled or oil-cooled and water-cooled would be adopted according to the voltage and power rating to ensure good heat dissipation. The high voltage transformer uses a distributed rectifier transformer. These characteristics give the series of power supplies very high reliability and extremely low energy storage. |
|||
Features | |||
|
|||
Optional functions | |||
|
|||
Block diagram & Principle description | |||
Working principle | |||
The IGBT full bridge inverter and the Series Resonant Tank circuit are the key components in this power supply. The series resonant inverter converts input voltage source to a equivalent current source, each pulsing is equivalent to an energy pack, which is sent to output load or output filtering capacitor after HV rectifying. Different output voltage and current corresponds to different output pulsing frequency, adjusting pulsing frequency leads to output voltage and current changes. |
|||
Functional parts | |||
The HP unit is made up of four different functional parts as shown below: | |||
|
|||
Rectifier Part
This stage takes three-phase 380Vac or 440Vac input, then after rectifies and filters, it creates a 600Vdc pulsing DC output.
High Frequency DC/AC Part
This stage uses an IGBT (Insulated Gate Bipolar Transistor) full bridge circuit to convert the pulsing DC to a high frequency AC waveform that feeds the next stage.
Series Resonant Tank Part
This part is an inductor in series with a capacitor. This LC network defines the characteristic impedance of the system and the frequency at which the AC current resonant.
High Voltage AC/DC Part
This part uses a transformer to step up the high frequency AC the necessary high voltage level. A rectifier circuit is then used to convert the high voltage, high frequency AC to the high voltage DC. |
|||
Specifications | |||
Input | Voltage | Three-phase 380Vac (input tolerance: 10%) | |
Frequency | 50Hz/60Hz | ||
Current | As per output power. | ||
Output | Rated power | 10KW (Max.) | |
Output voltage adjusting range | 0 ~ 60KV | ||
Output current adjusting range | 0A ~ 167mA | ||
Output polarity | Positive or Negative (both available) Client must choose one output polarity before ordering. |
||
Output voltage regulation precision | ≤0.1% | ||
Output voltage accuracy | ≤0.1% | ||
Line regulation | ≤0.1% for no load to full load at output. | ||
Load regulation | ≤0.1% for ±10% change in input voltage. | ||
Output connection | HV connector and line provided by IdealTek. | ||
Power factor | ≥0.92 | ||
Efficiency | ≥90% (measured @ 80% ~ 100% resistive load) | ||
Setting & Display | Output control mode | 10-turn potentiometer on front panel. | |
Display mode | 41/2 LED digital display | ||
Protection & Monitoring functions | Input protection | Input lack voltage and lack phase protection. | |
Output over voltage protection (OVP) | Output over voltage protection value settable. Power supply automatically cuts off output and alarms when output has over voltage. |
||
Over temperature protection (OTP) | Power supply automatically cuts off output and alarms when the internal temperature of the power supply exceeds power supply threshold value. | ||
Load discharging protection | When the load has discharging due to insufficient safety distance between load and ground, the power supply shutdown the high voltage output, and then restarts, so cycle like this till the discharging fault is eliminated. | ||
Short circuit protection | When a short circuit occurs between the load and the ground, the power supply works in constant current mode, the current is limited to the maximum value, and the voltage drops to 0 to protect the internal inverter from damage. | ||
Over current protection | When the users' load exceeds the rated load and cause over-loading, the power supply works in constant current mode, the power supply output current does not change, and output voltage decreases. | ||
Noise | ≤65 ~ 70dB | ||
Protection degree | IP20 | ||
Cooling method | Forced air cooling / Oil-immersed cooling. | ||
Working environment conditions | Ambient temperature | -10ºC~40ºC | |
Humidity | 10%~90%(non-condensing) | ||
Height | ≤2000m | ||
Storage environment conditions | Ambient temperature | -20ºC~60ºC | |
Humidity | 10%~90%(non-condensing) | ||
Height | ≤4000m | ||
Size (W*H*D) (mm) | 19" 9 ~ 10U cabinet with 800mm Depth | ||
Weight | Approx. 95 ~ 120Kg (depends on power rating) |
||
|
|||
Safety caution | |||
|
|||
Drawings (for reference only) | |||
19'' 9 ~ 10U cabinet (RAL7035) | |||
|