Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electrical Characteristics | |
1. Input Voltage | Tri-phase 208Vac |
2. Input frequency | 50 ~ 60Hz |
3. Input current | 6A@208Vac |
4. Output Voltage | 0 ~ 35KV, continuously adjustable |
5. Output current | 0 ~ 60mA, continuously adjustable |
6. Output polarity | positive or negative as customers' requirements |
7. Output adjusting mode | 10-turn potentiometer or 0~10V analog signal control or RS port. |
8. Line regulation | ≤0.5% |
9. Load regulation | ≤0.5% |
10. Ripple | ≤0.5% (measured @ 1uf load) |
11. Total Efficiency | ≥85% |
12. Temperature Coefficient | <200ppm/ºC |
13. Charging repeatability | ≤0.1% (measured @ 16uf load) |
14. Read output | Digital LED |
15. Output display | 41/2 digital meter |
16. Protections function |
|
17. Cooling | Forced air cooling |
18. Dimension | 19" sub-rack unit with 4U height and 600mm Depth |
19. Weight | approx. 12Kg |
Power switch | This switch is used to control AC input electric, when switch set to "ON" position, input electric comes in, when set to "OFF" position, input electric switched OFF. Do switch off this switch in maintenance! |
HV ON/OFF switch | HV started when set to "ON" position, HV shutdown when set to "OFF" position. |
Voltage adjustor | It is 10-turn potentiometer for output voltage adjusting, when turned to "10" position, output voltage rises its Max. value, when turned to "0" position, output voltage decreases to its Min. value. |
Current adjustor | It is 10-turn potentiometer for output current adjusting, when turned to "10" position, output current rises to its Max. value, when turned to "0" position, output current decreases to its Min. value. |
Output voltage meter | Display output voltage value |
Output current meter | Display output current value |
HV output terminal | HV output connector, easy and convenient installing |
Cooling fan | Ventilation direction: from inside to outside, keep the cooling duct clean for better ventilation. |
GND terminal | Make sure of good and tight GND connection for load and earth. Load must be connected to earth via this point. |
AC 220V Input | Standard 3-core AC 220V input terminal. |
Serial port-1 | RS232 communication port for remote contol |
Serial port-2 | N/A for this unit. |